Vertical frost and defrost chamber

to carry out frost resistance tests

The frost–defrost cycle chambers are designed to perform frost resistance tests and simulate automated freeze-thaw cycles according to international standards.

Its temperature range is -30 ºC up to +50ºC and its volume is 125 litres. They are mainly used in the construction sector, such as manufacturers of tile, slate, marble, brick, etc.

In Ineltec we design and manufacture customized equipment according to specifications, modifying or extending standard features. The frost-defrost chambers can be horizontal or vertical.

Characteristics
125 L
-30°C to +50°C
Other features on request
Standards

UNE-EN 10545-12 |  UNE 67028 EX  | UNE-EN 539-2 | UNE-EN 1343 | UNE-EN 12326-2 |  UNE 438-2 | UNE-EN 1341 | UNE EN 1348 | UNE-EN 12371 |  UNE-EN 491 | UNE-EN 1342 | UNE-EN 1367-1 | UNE 67048 | UNE-EN 494 |  NF P18-425 | NF P18-424 | etc. 

. . .
  • Temperature range: -30ºC up to + 50ºC
  • Volumen: 125 L
  • Temperature gradient: Ref.  1,5°C and Cal. 2°C (air) 
  • Accuracy: Temp. ±0,1ºC max. 
  • Homogeneity: Temp. ±0,5ºC max. 

Other features on request

Exterior: It is made of white lacquered aluminium sheet.

  • Furniture base: 4 height adjustable support legs in chamber, and tank with 6.
  • Viewing windows: A multi-glass peephole is located in the door to view the interior of the chamber.
  • Mobility: The machine has 4 multidirectional wheels with a braking device.

Interior: It is made of stainless steel and the exterior, of white lacquered aluminium sheet.

  • Sample holder: Sample holder element inside to hold 9 prismatic specimens.

Insulation: Through semi-rigid rock wool panels in accordance with EN 12667. Coefficient of thermal conductivity: 0.017 Kcal/m² h °C

Dimensions: (HxWxL)

Volume Inside dimension Outside dimension
125 L 400 x 400 x 400 2060 x 1200 x 1700

Approximately, as it depends on the temperature range, the outer dimension may be larger.

The touch screen PC has the PROCAM-WIN installed. It is easy and intuitive software which performs programming tasks, acquisition, records, control and analysis of the results. 

  1. Manual or automatic programming
  2. Possibility of programming date and time of the test
  3. It allows recording notes during the tests
  4. Different access levels
  5. Maximum 11 operators
  6. Display and recording of tests in a graphical or tabular table
  7. Export to excel or similar
  8. Setting of minimum and maximum alarms for temperature and humidity for each section
  9. It includes recording screen, incidences and maintenance.

Other related products Frost-defrost chambers

Subscribe to our Newsletter
and receive all our news
Sign up
You have to accept the terms of use..